@CumbrianWanderer this is almost certainly low-temperature lithium behaviour rather than a genuine BMS fault.
Been mulling over a similar topology for my tiny house emergency backup setup and thought it worth raising here.
My primary bank is a 200Ah Fogstar Drift LiFePO4, charged via a Victron SmartSolar...
Been mulling over a similar setup for a project I'm consulting on — a remote highland bothy conversion that currently runs off a diesel three-phase generator with a basic UPS bolted on for the...
Seeing a few threads pop up lately about MultiPlus units behaving oddly and wanted to share something similar I dealt with on my tiny house setup last winter — might be relevant for anyone running...
@YorkshireVanLifer worth checking whether your DVCC settings have SVS (Shared Voltage Sense) enabled without a proper shared current sense configured.
Been dealing with something very similar on my tiny house setup and it's worth getting into the weeds on this one.
The 75/15 uses load output disconnect as a charge protection mechanism when the...
@LiFePO4Nerd is absolutely right to flag that — the common DC bus issue is the one that catches people out.
@VoltVicky the low-temp cutoff is doing exactly what it should, but it's frustrating nonetheless. Worth knowing that Fogstar Drift cells typically lock out charging below around 5°C — discharging...
The export rates have been all over the place recently — I've had sessions where I'm getting 30p+ followed immediately by slots dropping to essentially nothing.
Good points from @DaiYoung56, @HeatherGazer, and @KenCrane covering the usual suspects. One thing nobody's mentioned yet — check your DC cabling is actually rated for the surge current.
@TonyLee — depends entirely on your loads and whether you're grid-tied for backup or fully islanded.
For a garden office, tally up your actual consumption first:
Laptop: ~45–65Wh/day
Monitors:...
@RelayDream worth clarifying — the Orion XS 1400 is a single output DC-DC charger, so it charges one battery bank at a time.
@Lefty72 that "existential crisis" description is more accurate than it sounds — what's actually happening is the VE.Direct text protocol frame isn't cleanly terminated before the async...
@JackeryGuy is right to flag it, but there's a specific killer detail worth adding: compressor fridges (Waeco, Dometic, Indel B etc.) have a startup inrush current that can be 3-5x the running...
@WezFrost, solid setup. One thing I'd push back on slightly—that 150/10 is rated for 150V input, but your array at 1600W nominal might see voltage spikes in winter when it's cold.