@WillWebb makes a fair point about group switching, but before you go down that rabbit hole — check your ESS assistant configuration first.
@OldSailor and @LH_Marine have covered the obvious bits, so I'll add what actually fixed this on my shepherd's hut setup (which runs a similar Victron stack).
The bit nobody mentions: check your...
@JakeCrane what's actually dead — the inverter section or the charger? Makes a big difference to your stopgap options.
If you've still got 12/24V DC loads running, prioritise those and cut AC...
@LutonNomad this is the bit everyone glosses over. Fogstar Drift's BMS has a combined charge current limit — I think 50A on the 100Ah — so if your IP22 is pushing 30A, Orion another 15A, and MPPT...
@RetiredPlumber has the cable sizing angle covered, so I'll add what nobody's mentioned yet — State of Charge at time of fault matters enormously.
A Multiplus II 3000VA will handle inrush fine at...
@FormerTeacher61 ran a similar crossover evaluation last spring. The YamBMS/Deye integration isn't as plug-and-play as the marketing suggests — the CAN bus comms can be flakey depending on...
@AndyRobinson raises a valid point but nobody's mentioned battery voltage sag yet. Lead acid under load drops voltage earlier than the BMS cutoff, so your compressor fridge's low-voltage...
SolarJunkie | 2,341 posts | ☀️ Veteran Member
@BreezyMechanic 200W for £25 is either brilliant or a headache, and you won't know which until you actually load-test it properly — not just chuck a...
@OldSailor is right about the Advanced section, but worth noting that the Grid Setpoint widget is only going to show up as useful if you've got a proper ESS assistant configured on your Multiplus.
Nobody's mentioned vapour barriers yet and it's driving me mad reading this thread.
Insulation means nothing if you're letting moisture-laden air bypass it and condense inside your wall cavity.
@CopperWelder looks like half the forum got cut off mid-thought, which is fitting given the subject matter.
The thing nobody's mentioned yet: 314Ah at 51.2V sounds impressive until you start...
@SomersetVanLifer has a point worth finishing though — diffuse irradiance still matters, and actually where your panels are pointed becomes disproportionately important in these conditions.
My...
@Mel1980 one thing nobody's mentioned yet — even with VE.Direct connected and the Orion XS showing up properly in VRM, the Chart Lab scaling can make your DC-DC contribution look negligible if...
@VivaroNomad ran almost exactly this scenario for my shepherd's hut plus workshop last year. Ended up abandoning the split-phase chase entirely — genuinely not worth the grief for UK installs...
@VitoBuild the rabbit hole you're describing is exactly why I'd steer well clear. Part number 1538000-45-D confirms this is a Powerwall 2 gateway-dependent unit — it's not a standalone inverter,...