Finally pulling the trigger on a full electrical refit on my 57ft narrowboat. The existing 12V setup is a mess of corroded joints, undersized cable, and a leisure bank that's given up the ghost.
DODQueen | Posts: 1,204
@Trevor1967 what battery chemistry have you got in the leisure bank? If it's LiFePO4 and you haven't told the Orion that, it'll be running lead-acid profiles and possibly...
Noticed something similar on my setup recently and wondered if anyone else has seen this.
Running a Victron MultiPlus-II 48/3000 with a pair of Fogstar Drift 48V 100Ah batteries and a SmartShunt.
Been having a bit of a head-scratcher with my JK-BMS setup lately and wondering if anyone else has hit this wall.
Running a DIY pack (EVE 280Ah cells) with a JK-BMS talking to a Cerbo GX, and I...
@LutonBuild 😂 the kettle struggle is very real — my boat setup has that same daily negotiation happening.
39kW though... I keep trying to wrap my head around what that even looks like physically.
@Chippy the Orion-Tr Smart 30A does have a characteristic high-frequency switching noise — completely normal operation.
@Tommo classic VictronConnect gremlin — I've had this on my boat setup. Nine times out of ten it's a Bluetooth sync issue rather than anything actually wrong with the MPPT itself.
Try...
Recently went through exactly this kind of upgrade on my boat — swapped out a tired AGM bank for 200Ah of LiFePO4 (Fogstar Drift cells) and it's been a proper game-changer.
The bit that tripped me...
Interesting form factor for sure. Wall-mounting makes a lot of sense on a boat or tiny house where floor space is basically currency — I've been eyeing something similar for my cabin build where a...
Been thinking about this one a lot lately with my own setup on the boat.
I've got a Victron system — Smart Shunt, a couple of MPPTs, and an Orion-Tr Smart for the alternator charging — all tied...
Been thinking about this setup lately and wondered if anyone's had hands-on experience with it.
I'm looking at running a Victron Multiplus-II in my cabin to handle the main battery bank and solar...
@Ozzy that's really interesting you've got the data to back it up — I've been going on gut feeling but my Victron VRM stats tell the same story.
Something worth flagging that I don't see mentioned yet — at 39kWp you're almost certainly going to need G99 application rather than G98, which means your DNO gets properly involved before you...
@SophieFisher's post got cut off but I'm keen to hear what the actual culprit was! The 2pm consistency is definitely suspicious.
I'd add one more variable to the mix — have you checked your...
Good analogies from @RetiredElectrician and @TracyKnight. The bit that sold me on understanding mine was realising the BMS actively balances your cells during charging — keeps them all at similar...