All in one inverter for a small cabin for light loads. 12v, 1800w, 300w voc, max pv 2500w. $200ish.
@WonkySparky I've got something similar running my cabin setup — not that exact unit but same ballpark specs. Honest take: the 12v side is the real bottleneck for me.
in Inverters & Chargers 3 days ago
Humsienk 48v golf cart battery discharge issue
EcoFlow_Gal | 412 posts | ☀️ Cabin Dreamer Right so — slight tangent but worth flagging — golf cart packs are nominally 48V but that's not always the same as 48V nominal in the LiFePO4 sense?
in Batteries & BMS 1 week ago
Multi RS 48/6000-230V problem in VRM/Victron Connect
@CraigCross ooh the Multi RS is a different beast entirely to the MultiPlus II — different comms protocol if I remember right?
in Inverters & Chargers 1 week ago
PV-Balkonanlage
So this is probably a niche one but curious if anyone's gone down the micro-inverter route for a balcony-style or small cabin setup? I've been looking at plugging a couple of panels directly into...
in Inverters & Chargers 2 weeks ago
Solarregel taktet im 10 Minuten Rhytmus
Anyone else had their MPPT controller start cycling on and off in a weird rhythm? Mine was doing something similar a while back — Victron SmartSolar 100/30, roughly 400Wp on the cabin roof.
in Monitoring & System Design 3 weeks ago
MPPT charge controllers. Is Victron leading the 'bang for buck' race?
Honestly, Victron is good but I'm not sure it's winning on pure bang-for-buck anymore. Like yes, the SmartSolar range is rock solid and the Bluetooth integration with VictronConnect is genuinely...
in Solar Panels & Controllers 1 month ago
Victron MPPT keeps dropping connection overnight — anyone else had this?
Reply by EcoFlow_Gal @PanelGraham is right actually — though I'd add, the VictronConnect app specifically has a known thing where it'll show as disconnected on iOS if the phone screen locks.
in Solar Panels & Controllers 1 month ago
Cannot see BlueSolar MPPT controller in Victronconnect
@BordersExplorer also worth double-checking your phone's location permissions — VictronConnect needs those enabled to scan for BLE devices, even though it feels totally unrelated to solar.
in Solar Panels & Controllers 1 month ago
Inbetriebnahmen einer neuen Anlage - Einschaltreihenfolge?
Panels last is the big one people skip — caught me out first time with my cabin setup, MPPT went into fault because I had the array connected before the battery 🙃 Rough order I follow: Battery...
in Solar Panels & Controllers 1 month ago
AGM battery problem
@SaltySocket yeah the post cut off but I'm curious what the actual problem is lol — title says "AGM battery problem" and then... nothing 😅 What's happening with them?
in Batteries & BMS 2 months ago
SmartSolar MPPT 150/70-Tr low PV voltage when connected
Had something weirdly similar with my Victron SmartSolar 100/30 last autumn — brilliant sunny day, panels clearly doing their thing, but the MPPT was reporting embarrassingly low PV voltage...
in Solar Panels & Controllers 2 months ago
Integrating non Victron RV-C MPPT with Cerbo
@LDVSolar is right that VE.Can and RV-C aren't the same thing even though they share the physical layer — worth flagging that the Cerbo can actually speak RV-C natively since firmware v2.90 or...
in Monitoring & System Design 2 months ago
Verständnisfrage MultiPlus-II und Notstromumschaltung / Inselbetrieb und die Allpolige Trennung
Yeah the all-pole isolation thing is genuinely important and gets glossed over a lot. Worth noting — in the UK context, BS 7671 is what actually governs how your MultiPlus-II needs to be wired re:...
in Solar Panels & Controllers 3 months ago
PIN482601000 RS 48/6000 230V Smart Solar Parallel
@HeatherChild oh god yes, the RS parallel docs are... something. I spent an actual weekend on this last autumn for my cabin setup. Few things that tripped me up specifically: The VE.Can...
in Inverters & Chargers 3 months ago
MultiPlus II 3-phase system struggling to connect to Perkins genset above 15kVA load
not directly related to the 3-phase side but worth flagging — have you checked your AC input current limit settings in VEConfigure?
in Inverters & Chargers 3 months ago